HDL-GCL H37P-050 · TECHNICAL DATA
Kontain HDL-GCL Heavy Duty 37 Polymer 050
Revision J · 7 November 2026
Heavy Duty 37 Polymer specifies ≥3,700 g/m² dry bentonite, a woven/nonwoven composite carrier and bonded 0.50 mm LDPE film.
Cover nonwoven ≥200 g/m²; carrier ≥300 g/m². P identifies polymer modification. Confirm the full grade code for supply.
Minimum order: 15,000 m².
Technical data.
Production acceptance uses the specified grade and traceable roll and lot test records. Values are specified minimum and maximum acceptance limits. Dry bentonite mass covers the clay fraction, excluding polymer, geotextiles, adhesive and PE. Film thickness is nominal. Select each construction against its stated property schedule. Modified swell: 16 h after the final increment in ASTM D1193 reagent water (distilled/deionised) or 20,000 mg/L NaCl. Supplier reference values are ≥28 mL/2 g in tap water and ≥22 mL/2 g in 20,000 ppm salt water on the supplier basis. The stated reagent-water and NaCl conditions define acceptance targets. ASTM D5890-25 excludes polymers. Agree fluid-loss preparation.
| Property | Method / basis | Value |
|---|---|---|
| Dry bentonite mass | ASTM D5993 plus formulation records | ≥3,700 g/m² excluding polymer |
| Cover nonwoven | ASTM D5261 | ≥200 g/m² |
| Carrier woven | ASTM D5261 | ≥100 g/m² |
| Carrier nonwoven | ASTM D5261 | ≥200 g/m² |
| Total carrier | Component minima | ≥300 g/m² |
| Bentonite formulation | Controlled source and formulation | Polymer-modified sodium bentonite powder |
| Nominal film thickness / resin | Nominal construction | 0.50 mm LDPE |
| Tensile strength MD / CMD | ASTM D6768 | ≥10 / ≥10 kN/m |
| Internal GCL peel | ASTM D6496 | ≥360 N/m |
| PE to cover peel | Agreed PE/nonwoven method; bonded areas | ≥300 N/m |
| CBR puncture | EN ISO 12236 | ≥2,500 N |
| Hydrated peak internal shear | ASTM D6243 | ≥35 kPa at 10 kPa normal stress |
| Powder grading | Validated particle-size method | ≥80% passing 75 µm |
| Moisture content | ASTM D5993 | ≤13% |
| Fluid loss | D5891-based modified-blend procedure | ≤18 mL |
| Modified swell in reagent water | ASTM D5890-based modified method; 16 h after final increment | ≥28 mL/2 g |
| Modified swell in saline liquid | ASTM D5890-based modified method; 16 h after final increment; 20,000 mg/L NaCl | ≥22 mL/2 g |
| Core conductivity in fresh water | D5084 with agreed GCL setup | ≤3.0 × 10⁻¹¹ m/s |
| Core conductivity in 20,000 mg/L NaCl | D6766 within scope; identify adaptations | ≤1.0 × 10⁻¹⁰ m/s |
| Fresh-water core index flux q10 | ASTM D5887; verify construction | ≤2.7 × 10⁻⁹ m³/m²/s |
| Released longitudinal film zone | Specified joint detail | 400 mm |
| Direct GCL contact / PE overlap | Separate widths at longitudinal joint | ≥300 / ≥300 mm |
| Extrusion sealing | Actual assembly procedure | Conditional on manufacturing and procedure qualification |
| Wedge welding | Current thin-film range | No |
Download the full TDS for the product construction and supply requirements.
Selection and installation.
GCL core values exclude PE and joints. Agree confinement, gradient, hydration, liquid and equilibrium criteria. For chemicals, use ASTM D6766 within scope and report adaptations. Specify durability, cycling and protection testing to suit the application. Consider polymer where higher drying resistance is sought during prolonged exposure, or lime-affected water, highly saline water or certain leachates may hydrate the clay instead of typical rainwater. Verify the actual liquid and formulation. Cover promptly; permanent exposed service requires separate design. Specify the 0.50 mm film and extrusion procedure for the actual filler and laminated assembly, with procedure trials before installation. No wedge welding. Use issued end-joint and repair details. Film is specified by resin type and nominal thickness; select GCL-W for a GM17 membrane. Agree order dimensions and cores.
Common rolls are 5 m × 30 m (150 m² gross). Custom dimensions, bentonite masses and plastic or steel cores are available by order. Confirm gross roll mass and clear core bore before lifting.
Provide the liner section, contact-soil grading and chemistry, liquid analysis, slope, loading, installation method and delivery requirements.
Read the installation guidance →