An integral polymer barrier to reduce direct exposure from the covered face and help manage moisture loss and wetting–drying effects. Retain confinement and the specified GCL sealing detail.

Specify 0.2 or 0.5 mm PE, or a custom 1.0 or 1.5 mm smooth LLDPE laminate with GRI-GM17 membrane targets and qualification before supply. Standard and heavy bases are selected separately.

Reference specification.

The 1.0 / 1.5 mm figures are smooth black LLDPE membrane specification targets. They are not test results for a finished laminated GCL. Confirm trial manufacture, winding, the processed formulation, bond and joint performance before supply. Full membrane requirements are in the TDS.

PropertyMethod / basisValue
Nominal laminate optionsOrder schedule0.2 / 0.5 mm PE; 1.0 / 1.5 mm LLDPE
Base GCLSeparate selected-grade scheduleStandard or heavy composite base
Average smooth LLDPE thicknessASTM D5199; GM17 target≥1.00 / ≥1.50 mm
Lowest individual LLDPE thicknessASTM D5199; GM17 target≥0.90 / ≥1.35 mm
LLDPE tensile break strengthASTM D6693; GM17 target≥27 / ≥40 kN/m
LLDPE break elongationASTM D6693; GM17 target≥800% for both
Initial Standard OIT OR HP-OITASTM D8117 OR ASTM D5885≥100 min OR ≥400 min
Oven ageing, 90 days at 85°CGM17 retained OIT targets≥35% Standard OIT OR ≥60% HP-OIT
UV exposure, 1,600 hGM17 retained HP-OIT target≥35%

Review the full TDS for the construction, tolerances, test conditions and supply requirements. These values are not a statement of lot-specific conformance.

Selection and installation.

Field welding is limited to qualified LLDPE laminate ≥1.0 mm with suitable free flaps, verified GM17 formulation/OIT/ageing evidence and qualified weld trials and seam testing. HDPE is excluded from this welded option. Thin PE laps remain loose under accepted confinement and do not form a continuous welded membrane barrier. Lamination does not remove the need to assess contact chemistry, edges, penetrations or the underside.

Common rolls are 5 m × 30 m (150 m² gross). Custom dimensions, bentonite masses and plastic or steel cores are available by order. Confirm gross roll mass and clear core bore before lifting.

Provide the liner section, contact-soil grading and chemistry, liquid analysis, slope, loading, installation method and delivery requirements.