Australia-based · Global geosynthetic supply & engineering support | Site investigations · SAGCL technical documents (10)
← All Kontain GCL products

GCL H37U · TECHNICAL DATA

Kontain GCL Heavy Duty 37 Unmodified

Revision F · 7 November 2026

Heavy Duty 37 specifies ≥3,700 g/m² dry bentonite, a 300 g/m² composite carrier (100 woven plus 200 nonwoven) and sodium bentonite powder without polymer addition.

Needle-punched GCL without a PE laminate. Cover nonwoven ≥200 g/m². Carrier composite ≥300 g/m²: woven ≥100 and nonwoven ≥200 g/m². Selected source: Indian sodium bentonite powder. See the bentonite source data and BPEM criteria below.

Minimum order: 3,000 m².

Technical data.

Production acceptance uses the specified grade and traceable roll and lot test records. Values are specified minimum and maximum acceptance limits. Dry bentonite mass covers the clay fraction, excluding polymer and geotextiles. Select each construction against its stated property schedule. ASTM D5890: reagent water (distilled/deionised), at least 16 h after the final increment; extend/report as the method requires. Specify source and batch declarations for the unmodified sodium bentonite. Select saline applications using liquid-specific compatibility testing.

PropertyMethod / basisValue
Dry bentonite massASTM D5993 plus formulation records≥3,700 g/m² excluding polymer
Cover nonwovenASTM D5261≥200 g/m²
Carrier wovenASTM D5261≥100 g/m²
Carrier nonwovenASTM D5261≥200 g/m²
Total carrierComponent minima≥300 g/m²
Bentonite formulationControlled source and formulationSodium bentonite powder; no polymer addition specified
Tensile strength MD / CMDASTM D6768≥10 / ≥10 kN/m
Internal GCL peelASTM D6496≥360 N/m
CBR punctureEN ISO 12236≥2,500 N
Hydrated peak internal shearASTM D6243≥35 kPa at 10 kPa normal stress
Moisture contentASTM D5993≤13%
Fluid lossASTM D5891 within scope≤16 mL
Unmodified swell in reagent waterASTM D5890; minimum 16 h after final increment≥24 mL/2 g
Core conductivity in fresh waterD5084 with agreed GCL setup≤3.0 × 10⁻¹¹ m/s
Fresh-water core index flux q10ASTM D5887; verify construction≤2.7 × 10⁻⁹ m³/m²/s
Factory longitudinal edge overlapAccepted seam detail≥300 mm
End joints and field cuts on a baseAccessory bentonite treatment≥600 mm
Roll width and lengthCommon supply format5 × 30 m

Download the full TDS for the product construction and supply requirements.

Bentonite quality for Australian projects.

Kontain’s non-polymer GCL range uses Indian sodium bentonite powder. Choose unlaminated GCL, 0.20 / 0.50 mm film laminates or 0.75 / 1.00 mm GM17 LLDPE weldable laminates to suit the lining design.

The bentonite supplier reports more than nine years supplying an established Malaysian GCL manufacturer whose products are supplied into Australia.

Minimum orders: 15,000 m² for 0.20 / 0.50 mm film laminates; 20,000 m² for 0.75 / 1.00 mm weldable GM17 LLDPE laminates; 3,000 m² for unlaminated GCL.

Unmodified bentonite source data

Supplier-declared specification limits for the selected Indian sodium powder.

PropertySupplier declaration
Origin and formIndian sodium bentonite powder
Polymer modificationNone
Montmorillonite content≥75%
Methylene blue adsorption≥300 mg/g
Swelling≥25 mL (supplier reporting basis)
Fluid loss≤18 mL
Water adsorption capacity≥550%; DIN 18132 Enslin–Neff
Particle size≥80% passing 75 µm
Cation exchange capacity≥70 meq/100 g
Moisture content≤13%
Calcium concentration<2%

Selected BPEM numerical criteria

The supplier-declared montmorillonite content, cation exchange capacity and powder grading meet the corresponding numerical criteria in EPA Victoria’s BPEM Appendix E6.1. These source properties apply to the non-polymer range.

PropertyBPEM criterionSupplier specification
Montmorillonite>70 wt%≥75%
Powder particle size80% passing 75 µm (BPEM example)≥80% passing 75 µm
Cation exchange capacity≥70 meq/100 g≥70 meq/100 g

For BPEM projects, specify source certification, carbonate content, bentonite quality criteria, swell-test conditions and batch verification in the project quality plan. Link the bentonite and GCL quality records to the supplied rolls, with project-specific chemical compatibility, design and installation CQA.

Source data are supplier-declared specification limits. Swelling is quoted on the supplier’s reporting basis; the GCL schedule defines the acceptance methods and units. Reference: EPA Victoria Publication 788.3, Appendix E6.1. Read the BPEM reference ↗

Selection and installation.

Hydraulic limits apply to the GCL under agreed confinement, gradient, hydration, liquid and equilibrium criteria. Assess joint performance separately. Use ASTM D6766 within scope for chemicals and report adaptations. Specify durability, cycling and protection testing to suit the application. Select for compatible low-salinity rainwater or subgrade moisture. Consider the polymer grade for greater drying resistance or aggressive hydration liquids, with formulation-specific testing. Cover promptly; permanent exposed service requires separate design. Keep overlaps clean and in direct GCL contact under continuous confinement. Confirm factory edge treatment; use compatible accessory bentonite on untreated seams, ends and cuts. Slope end joints and repairs require project details. Agree roll dimensions and cores for the order.

Common rolls are 5 m × 30 m (150 m² gross). Custom dimensions, bentonite masses and plastic or steel cores are available by order. Confirm gross roll mass and clear core bore before lifting.

Provide the liner section, contact-soil grading and chemistry, liquid analysis, slope, loading, installation method and delivery requirements.

Read the installation guidance →