Heavy Duty 37 specifies ≥3,700 g/m² dry bentonite, a 300 g/m² composite carrier (100 woven plus 200 nonwoven) and polymer-modified sodium bentonite powder.

Needle-punched GCL without a PE laminate. Cover nonwoven ≥200 g/m². Carrier composite ≥300 g/m²: woven ≥100 and nonwoven ≥200 g/m².

Technical data.

Exact-grade manufacturer acceptance and traceable production verification are required. Specified lower and upper supply limits, not MARV. Dry bentonite excludes polymer and geotextiles; verify the clay fraction. Confirm each unlaminated construction; added clay mass does not establish higher performance. Modified swell: 16 h after the final increment in ASTM D1193 reagent water (distilled/deionised) or 20,000 mg/L NaCl. Supplier ≥28/≥22 values used tap/unspecified salt water; defined conditions need confirmation. ASTM D5890-25 excludes polymers. Agree fluid-loss preparation.

PropertyMethod / basisValue
Dry bentonite massASTM D5993 plus formulation records≥3,700 g/m² excluding polymer
Cover nonwovenASTM D5261≥200 g/m²
Carrier wovenASTM D5261≥100 g/m²
Carrier nonwovenASTM D5261≥200 g/m²
Total carrierComponent minima≥300 g/m²
Bentonite formulationControlled source and formulationPolymer-modified sodium bentonite powder
Tensile strength MD / CMDASTM D6768≥10 / ≥10 kN/m
Internal GCL peelASTM D6496≥360 N/m
CBR punctureEN ISO 12236≥2,500 N
Hydrated peak internal shearASTM D6243≥35 kPa at 10 kPa normal stress
Powder gradingValidated particle-size method≥80% passing 75 µm
Moisture contentASTM D5993≤13%
Fluid lossD5891-based modified-blend procedure≤18 mL
Modified swell in reagent waterASTM D5890-based modified method; 16 h after final increment≥28 mL/2 g
Modified swell in saline liquidASTM D5890-based modified method; 16 h after final increment; 20,000 mg/L NaCl≥22 mL/2 g
Core conductivity in fresh waterD5084 with agreed GCL setup≤3.0 × 10⁻¹¹ m/s
Core conductivity in 20,000 mg/L NaClD6766 within scope; identify adaptations≤1.0 × 10⁻¹⁰ m/s
Fresh-water core index flux q10ASTM D5887; verify construction≤2.7 × 10⁻⁹ m³/m²/s
Factory longitudinal edge overlapAccepted seam detail≥300 mm
End joints and field cuts on a baseAccessory bentonite treatment≥600 mm
Roll width and lengthCommon supply format5 × 30 m

Download the full TDS for the product construction and supply requirements.

Selection and installation.

Hydraulic limits apply to the GCL under agreed confinement, gradient, hydration, liquid and equilibrium criteria. Assess joint performance separately. Use ASTM D6766 within scope for chemicals and report adaptations. Durability, cycling and protection qualification remains pending. This sheet does not establish landfill-specification compliance. Consider polymer where higher drying resistance is sought during prolonged exposure, or lime-affected water, highly saline water or certain leachates may hydrate the clay instead of typical rainwater. Verify the actual liquid and formulation. Cover promptly; permanent exposed service requires separate design. Keep overlaps clean and in direct GCL contact under continuous confinement. Confirm factory edge treatment; use compatible accessory bentonite on untreated seams, ends and cuts. Slope end joints and repairs require project details. Agree roll dimensions and cores for the order.

Common rolls are 5 m × 30 m (150 m² gross). Custom dimensions, bentonite masses and plastic or steel cores are available by order. Confirm gross roll mass and clear core bore before lifting.

Provide the liner section, contact-soil grading and chemistry, liquid analysis, slope, loading, installation method and delivery requirements.

Read the installation guidance →